| 快速激光对中仪GO
Continue by rotating the shafts to the 3 or 9 o’clock position for adjustments in the horizontal direction. Once again, the angle guide will help you with reaching the right position. Move the machine until the values for both angular and parallel alignment are within tolerance, where the arrows again help out with which direction to choose.Complete the laser alignment process by rotating the shafts back to the 12 or 6 o’clock position to verify that the machine’s alignment status is within tolerance. To confirm the result, redo the measurement. The Fixturlaser GO Software Package
Fixturlaser GO Features Several of its features are adopted from the innovative Fixturlaser XA system, which will reduce the time spent on pre-alignment actions, measurement registration, performing the actual alignment, remeasuring to make certain that you have a correctly aligned machine; and, finally, documenting the measurement data.
The three LED lights on the display unit indicate whether the couplings are within tolerance (green light), within double tolerance (orange light), or out of double tolerance (red). Other characteristics facilitating the handling of the system are the icon based user interface, a typical Fixturlaser trademark, now used in our systems for more than 15 years.
|
Components
![]() Fixturlaser GO Display Unit
Display unit with housing material of high impact ABS plastic. It has the dimensions 205 x 116 x 56 mm and weighs 0,7 kg with batteries.
![]() Measuring Units
Housing material of anodized aluminum and high PC/ABS plastic over molded with TPE rubber. Measurement distance is up to 10 m (33 feet). The measuring units have a detector length of 30 mm (1,2 in).
![]() Shaft bracketShaft bracket made of anodized aluminum with a width of 20 mm. It allows for measurements with a shaft diameter of 20 - 175 mm (standard chain), with extension chain up to 450 mm. |
|